Modification of Seal Systems

Application

Mechanical seal system of catalytic reactor, variable pressure working condition, gas-liquid-solid three-phase   medium, pressure 0 ~ 3.0MPa, normal temperature ~ 230 ℃.

Before   transformation

The sealing system adopts Plan53C system conforming to API682 standard.

Existing problems

圖片2.png

Transformation measures

Upgrade P53C system and adopt EIO sealing control system.

Transformation achievements

Less media leakage, Less reaction failure.

No overpressure leakage, No repeated impact.

Less mechanical seal failure, Less media failure.

Less safety accidents, Less shutdown.

Industry

Petroleum, Chemical industry